09: The power estimate and how it was calibrated

The firmware publishes the A/C’s power, voltage and current from bytes the unit already sends on the bus, and Home Assistant’s Energy dashboard can use the result. This page says what the numbers are, how far to trust them, and how the one constant behind them was measured. Read it before you rely on the kWh figure, or if you want to calibrate against your own meter.

What is published

Entity Source
Power (W) 4.15 * raw^2, where raw is status byte 55. Unknown above the hub’s max_power
Voltage (V) status byte 50, in whole volts as the unit reports it
Current (A) derived: P / (V * 0.95). Unknown when the power is
Energy today (kWh) ESPHome’s total_daily_energy on the Power sensor, in packages/hisense-ac.yaml

The values are published when they change and at least once a minute. Power and current read 0 while the compressor is off. The energy sensor integrates on the node with method: left (the value between two updates is the older one) and resets at midnight. Home Assistant’s long-term statistics hold the history.

The model is active_power_mw() and active_current_ma() in firmware/esphome/components/hisense_ac/hisense_telemetry.h, pure functions with host tests (test_esphome_codec_parity.cpp holds them equal to the reference in firmware/test/reference-driver/power_estimate.h for every byte value the reference does not clamp, and test_esphome_map_gaps.cpp covers their bounds).

The limit: max_power

An estimate above the hub’s max_power option (watts, default 5000, 500 W to 50 kW) is not published as a number. Power goes out as unknown, and so does current, since it is computed from the power. power_reading() in the same header makes that decision, with its own host tests.

The estimate is the square of one byte, and nothing but the frame checksum guards that byte: a value of 255 reads as 270 kW. Before this limit the firmware clamped the estimate at 50 kW and published it, and the energy sensor summed it. 5 kW is generous for a single-split residential unit (the highest point in the calibration below is 934 W, raw 15). With the default, raw 34 (4797 W) is the highest value published and raw 35 (5084 W) the first that is not.

What an unknown stretch does to the energy figure: ESPHome’s total_daily_energy ignores an unknown value, so nothing is added while it lasts, and the next reading adds the whole gap at the last power published before it (method: left). A long run of bad bytes during a change of load is therefore counted at the old load. An unknown value is published once and then with the once-a-minute refresh, not with every status frame.

How far to trust it

It is an estimate, not a meter. These inverter splits almost never carry a revenue-grade meter, and the vendor’s cloud figure is an estimate too: either a value the indoor MCU reports (it senses bus or compressor current for inverter control) or a model from compressor frequency and mode.

  • The constant comes from two non-zero points on one unit. The quadratic fits both to under 1 %, which supports the shape, but a third steady point was never taken.
  • The power factor is assumed (0.95, typical for an inverter with active PFC). At deep part load the real power factor is lower.
  • Byte 50 reads about 6 % below a panel meter (about 220 against 234 to 236 V). The power figure does not depend on it. The derived current does.
  • The only plausibility check on byte 55 is max_power (above). A wrong byte that still gives an estimate under the limit is published as a reading.
  • No comparison against the vendor app’s numbers is on record.

The calibration

Reference: a PD3-63VA panel meter on the phase the A/C is on (L3). Three points, matched by time (photo EXIF against the logger’s [HH:MM:SS]). Power is V * dI(L3 minus baseline) * PF(0.95):

Time L3 A dI (A/C) P (W) byte 55 byte 42 (Hz)
22:07:36 1.1 0.0 0 0 0
22:12:32 2.3 1.2 268 8 31
22:10:48 5.3 4.2 934 15 68

Byte 55 tracks the square root of power, not amps. A linear fit gives incompatible slopes (33 against 62 W per count). A quadratic through the origin fits both load points to under 1 %:

P_watts = 4.15 * raw55^2        (PF 0.95 folded in)
  raw 8  -> 266 W (meter 268)     raw 15 -> 934 W (meter 934)

The derived current, for comparison: raw 15 gives 4.47 A (meter 4.2), raw 8 gives 1.27 A (meter 1.2). Byte 60 gives the same curve (about 0.66 * raw60^2) as a cross-check. The tap that logged the frames has since been removed, so a fourth point is deferred.

The bytes behind it

From the three-state correlation in reverse-engineering/docs/03-rs485-ac-protocol.md (cool at 60 Hz, off at 0 Hz, heat at 50 Hz, mapped 2026-07-07):

Byte Field Confidence Use
50 supply voltage (V) high: 218 V loaded, 222 V idle (sags under load), consistent with 230 V mains the Voltage sensor
55 (= 145) first labelled “phase or bus current A”: zero when the compressor is off, tracks load. The calibration showed it follows the square root of power calibrated above the Power sensor
56 (= 144) “phase or bus current B” medium not used
60 “active current or power reading”, on the same curve as byte 55 medium cross-check only
42 compressor frequency, actual (Hz) confirmed the Compressor frequency sensor
41, 43 compressor frequency, target (Hz) confirmed not used
45 outdoor (condenser) coil temperature (°C) confirmed (reverses between cool and heat) the Coil temperature sensor

What was planned and not built

  • A frequency model as a second path (P = a * comp_freq + b * fan_level + P_standby), which is what most community inverter A/C integrations use. It would not depend on byte 55 and could bound it. It was never implemented, so there is no cross-check at run time.
  • A fitting script (tools/fit_power.py) for a least-squares fit from recorded pairs. It was never written. The constant above was fitted by hand.
  • Coefficients that can be changed without a rebuild. The constant is compiled in (POWER_MW_PER_COUNT2).
  • A lifetime energy counter on the node. The reference power_estimate.h carries a pure, host-tested integrator pair (hisense_energy_add, hisense_energy_mwh) that nothing calls: a lifetime counter would need persistence to survive a restart. total_daily_energy and Home Assistant’s statistics do the job.

On the retired Matter builds (tag matter-final) the same three values were attributes of ElectricalPowerMeasurement on endpoint 1, and energy was left to a Riemann-sum helper in Home Assistant. That cluster is delegate-based in connectedhomeip, which made it the most awkward endpoint of those builds.

Calibrating against your own meter

You need a reference that reads the A/C alone: a clamp meter on the A/C’s live conductor, or a panel meter on its circuit with the baseline subtracted. A clamp that reads true power (W) is best. One that reads only amps gives apparent power, and you have to assume a power factor.

Safety. This means working at the mains lead of the A/C. Clamp around a single insulated conductor, never bare metal. If the terminal block is not safely reachable, clamp at the isolator or the plug lead. Do not open anything live that you are not qualified to open.

  1. Log byte 55 next to the meter. With the node’s log at VERY_VERBOSE the raw status frames are in the log. With a tap on the bus, reverse-engineering/tools/decode_ac_frames.py --port <tap> decodes them, and firmware/esp32-recon/ shows them on a console.
  2. Hold three or four steady states and note the meter at each: off, a low cool (about 40 Hz), a hard cool or turbo (about 69 Hz), heat (about 50 Hz).
  3. Fit k in P = k * raw^2 through the origin and compare with 4.15.
  4. A different constant goes into POWER_MW_PER_COUNT2 in hisense_telemetry.h and into the reference power_estimate.h, in one commit, or the parity test fails. Say in the commit what it was measured with.