Entities and Diagnostics

Every entity a node exposes, what each means, and how to read the diagnostics that tell you whether the node and the A/C are talking. For day-to-day use see Everyday Control. For a fault you can name, start at Troubleshooting and FAQ.

The list below is what the shipped board files give. A test pins it: the host end-to-end test compares the node’s entities with firmware/test/host_e2e/entities.golden.json on every change to the firmware. Entity ids are shown for the default device name, Air Conditioner.

Entities

Climate

climate.air_conditioner: mode (off, cool, heat, fan_only, dry, auto), target temperature (16 to 32 °C, step 1), fan (auto, low, medium_low, medium, medium_high, high), swing (off, vertical), 13 presets, the room temperature and the current action. The presets and the limits are in Everyday Control.

Controls

Name Entity id What
Eco switch.air_conditioner_eco eco mode
Turbo switch.air_conditioner_turbo turbo mode
Quiet switch.air_conditioner_quiet quiet mode (the unit’s mute flag)
Panel display switch.air_conditioner_panel_display the display on the indoor unit
Beeper switch.air_conditioner_beeper whether the unit beeps for this node’s commands (below)
Sleep profile select.air_conditioner_sleep_profile Off, General, Old, Young, Kids

Sensors

Name Entity id Unit What
Outdoor temperature sensor.air_conditioner_outdoor_temperature °C from the outdoor unit
Coil temperature sensor.air_conditioner_coil_temperature °C the outdoor (condenser) coil
Compressor frequency sensor.air_conditioner_compressor_frequency Hz how hard the compressor runs
Power sensor.air_conditioner_power W an estimate. The bus carries a current reading that is a proxy and not amps, and the firmware computes power from it (firmware/docs/09-energy-monitoring.md). Unknown when the estimate is above max_power (5 kW unless set), which the firmware takes for a bad byte on the bus
Voltage sensor.air_conditioner_voltage V as the unit reports it
Current sensor.air_conditioner_current A derived from the power estimate and the voltage. Unknown when the power is
Energy today sensor.air_conditioner_energy_today kWh the power estimate summed over the day. An unknown power value adds nothing of its own. The day rolls over on Home Assistant’s clock
Aux heat relay binary_sensor.air_conditioner_aux_heat_relay   on while the auxiliary heater runs
Fault binary_sensor.air_conditioner_fault   on while the unit reports any fault

Diagnostics

Name Entity id What
AC bus link binary_sensor.air_conditioner_ac_bus_link on while the unit answers its status poll
AC device type sensor.air_conditioner_ac_device_type the two bytes the unit reports about itself in the handshake, as HH LL. Unknown until learned
Bus checksum errors sensor.air_conditioner_bus_checksum_errors bus counters
Bus reply timeouts sensor.air_conditioner_bus_reply_timeouts  
Bus link losses sensor.air_conditioner_bus_link_losses  
Unanswered commands sensor.air_conditioner_unanswered_commands  
Command retries sensor.air_conditioner_command_retries  
Failed commands sensor.air_conditioner_failed_commands  
Capability heat pump, Capability eco, Capability quiet binary_sensor.air_conditioner_capability_* what the unit says it supports (below)
Fault indoor temp sensor, Fault indoor to outdoor comms, Fault condensate tray full, Fault outdoor temp sensor binary_sensor.air_conditioner_fault_* one fault bit each
Uptime, WiFi signal, Reset reason   the node itself. The wording of the reset reason is the chip’s own and differs between platforms
Start Wi-Fi setup a button opens Wi-Fi setup mode
Serial port restarts, Flash layout   the stock module only (The Stock Module)

The six bus counters and the per-bit Fault ... sensors are disabled by default: a node added to Home Assistant shows them under “disabled entities” on the device page, and you enable the ones you want there. The summary Fault sensor and AC bus link are always enabled. Home Assistant applies this only when it first sees an entity, so on a node it already knows they stay enabled.

The node’s own diagnostics and the button come from packages/node.yaml, and the stock module’s two from packages/amebaz2.yaml. They are not in the golden file, which covers the A/C’s entities.

Capability and fault flags

The A/C reports what it supports in its ProductType reply, and its faults as a bitmap. The component can publish every bit as a binary sensor. The shipped package declares three capability flags and four fault flags, the ones that have fired on a bench unit. The rest are options you add to packages/hisense-ac.yaml in the same way:

Group Options
Capability flags (13) capability_cool_heat, capability_power_save, capability_fan_mute (the three shipped), capability_ai, capability_infinite_fan, capability_swing_dir_8, capability_swing_follow, capability_humidity, capability_heat_8c, capability_purify, capability_q_display, capability_enable_8heat, capability_trans_102_64
Fault flags (18) fault_indoor_temp, fault_indoor_comms, fault_water_full, fault_outdoor_temp (the four shipped), fault_indoor_coil_temp, fault_indoor_humidity, fault_indoor_fan_motor, fault_grille, fault_indoor_vzero, fault_indoor_display, fault_indoor_keys, fault_indoor_wifi, fault_indoor_ele, fault_indoor_eeprom, fault_outdoor_eeprom, fault_outdoor_coil_temp, fault_outdoor_gas_temp, fault_over_temp

A capability flag that is off means “not on this unit”, never “not on this model”. What each flag stands for is in reverse-engineering/docs/11-model-capability-map.md.

Behaviour worth knowing

Situation What the firmware does
A command the unit does not take sent again (confirm and retry)
A command before the first status frame after boot, or while the unit is not answering refused. The entity keeps its state
A mode request to a unit that is off one frame that carries the mode and power-on
A setpoint outside cool and heat refused by the entity in auto, dry and fan-only (the unit keeps its own)
A fan change under turbo, quiet or a sleep profile refused
Special modes changed together 10 s between special-mode frames, because the unit ignores one that lands too soon after another. Changes that undo each other within that time merge into one frame
A status that contradicts a command just sent ignored for 4 s, so the entity does not flicker back
Outdoor and coil temperature after a power cut for a while after mains power returns the unit reports both as exactly -20 °C, a placeholder. They show as unknown until real readings arrive. A real -20 °C is shown once the unit has reported anything else since the node started. (One observation, one unit, 2026-10-10.)

Beeper

The indoor unit beeps when it takes a command. The beep is requested per frame: bit 2 of byte 23 in a command frame, which the vendor module sets by default. The Beeper switch clears that bit on every command frame the node sends.

  • Turning the switch off sends nothing. It takes effect from the next command.
  • The setting is stored on the node and survives a reboot. It is on by default.
  • The remote control still makes the unit beep. That path does not go through the node.
  • The A/C does not report a beeper state, so the switch shows what was last set.

A unit was heard to stay silent with the switch off (maintainer’s check, 2026-10-10).

Bus counters

The counters start at 0 at boot and return to 0 on a restart. On a newly added node they are disabled in Home Assistant until you enable them on the device page (Diagnostics).

Counter Counts
Bus checksum errors frames from the unit that arrived with a bad checksum
Bus reply timeouts frames of any kind the unit did not answer within 500 ms
Unanswered commands the reply timeouts that were commands. One command lost three times counts 3
Bus link losses times the link was declared lost: five status polls in a row without a valid reply
Command retries commands sent again, for either reason in confirm and retry
Failed commands commands given up on after the last re-send, plus commands dropped at a link loss, and a special-mode write the queue could not take

How to read them:

  • All zero, bus link on: healthy.
  • Reply timeouts rising, bus link on: the unit misses some polls. Occasional misses are harmless, because the next poll asks again.
  • Unanswered commands rising: a send was lost. If Failed commands did not rise too, a re-send landed and nothing was lost in the end.
  • Link losses rising: the unit stopped answering for at least five polls. Check the wiring and the DE pin (the bus link stays off).
  • Checksum errors rising: corrupt bytes on the wire. Usually wiring, a floating DE line or a marginal supply.

Log lines

The component logs under the tag hisense_ac. Read the log with esphome logs <board file>, or in the ESPHome dashboard. The deployed level is INFO.

Line Level Meaning
A/C bus link lost: the unit is not answering WARN five status polls in a row went unanswered
A/C bus link restored INFO the unit answers again
Frame with a bad checksum dropped (N since boot) WARN a damaged reply. Counted in Bus checksum errors
Command refused: no status from the unit yet WARN a climate command arrived before the first status frame after boot
Command not sent: no status from the unit yet, so the frame would carry defaults WARN the same for eco and turbo, whose frame is built from the unit’s status
Command refused: the unit is not answering WARN a command arrived while the bus link was down
Target temperature refused: the unit only takes one in cool and heat WARN a setpoint in auto, dry or fan-only
Fan change refused: turbo, quiet or sleep is holding the fan speed WARN clear the preset first
Command frame dropped: TX queue full, Special-mode queue full, op N refused WARN more commands at once than the node queues. The entity keeps its state
Command frame got no reply from the unit, sending it again WARN the first check of confirm and retry failed
Command not taken by the unit (fields 0x...), sending it again (N of M) WARN the second check failed
Command taken by the unit after N re-send(s) INFO a re-send landed
Command not taken by the unit after N re-send(s) (fields 0x...), showing what it reports WARN given up. Counted in Failed commands
N command(s) unconfirmed or unsent when the link dropped, not sent again WARN open commands dropped at a link loss
A/C reports a fault: bitmap 0x... WARN a real fault. A/C fault cleared at INFO when it goes
Setup requested from the remote (0x1E reply request bits 0x..) INFO the “77” gesture was seen (Wi-Fi setup mode)

To see more, raise logger: level: in the node’s YAML. DEBUG adds each status change and every command sent. VERY_VERBOSE adds the raw bytes of every frame in both directions, which is the level to use when the A/C does not answer. The full table of levels is in firmware/esphome/README.md (“Log levels”).

Confirm and retry

The node checks each command twice.

Check When If it fails
The unit replied to the frame within the 500 ms reply window the frame is sent again in the next bus cycle, ahead of anything queued behind it. Three sends at most, and only while the unit answers its status poll
The unit’s status shows what was asked the first status frame about 4 s after the frame left the wire power, mode, setpoint, fan and swing are sent again, twice at most. Eco, turbo, quiet and sleep are planned again from what the unit reports, once, after the 10 s special-mode pacing

After the last re-send the node logs a warning, counts the command in Failed commands, and lets the entities show what the unit reports. A newer command replaces the one being checked. A lost bus link drops every open command.

A mode request to a unit that is off is one frame that carries the mode and power-on together, as the vendor module sends it. If the unit is still off at the check, the re-send falls back to two frames, power-on and then the mode.

Limits:

  • Some differences are never re-sent, because they are the unit’s own behaviour: its setpoint in auto, dry and fan-only, the mode, setpoint and fan that turbo forces, the fan under quiet or a sleep profile, and anything except power on a unit that reports off.
  • A value that is neither the old one nor the requested one is taken as someone using the remote. The command is dropped without a failure count.
  • Display and beeper are not confirmed. The unit reports neither.
  • The acknowledgement byte in the unit’s reply is logged and nothing is decided on it. Its layout is read from the vendor image and has not been captured on this bus. The status check is what tells a command that took from one that did not.
  • Commands older than 20 s are not sent again.
  • The one-frame power and mode bytes for auto, dry and fan-only have not been captured from the vendor module. Only cool and heat appear in its image. The others follow the same rule and are marked VERIFY in the source. The two-frame fallback covers a unit that does not take them.
  • Hardware coverage is thin. Before this existed, runs on two units failed about one check in 52, each time with exactly one unanswered command (pull request #179). On the two units that then ran the new code, a full actuation run showed no retries (maintainer’s report, 2026-10-10), so the re-send path has not been seen to fire on a real unit. It is covered by host tests and by the host end-to-end test (Testing and QA).

The rules are pure functions in firmware/esphome/components/hisense_ac/hisense_confirm.h (intent_expected_fields(), confirm_decision()), carried out by the command tracker in hisense_commands.h.